HomeProductsTP 2007
Time & Pressure Tester, Reach items & UN transport standard of goods hazard Tester, TP 2007, Time & Pressure Tester, HAZARD TEST
FESTEC¡¯s Time & Pressure Tester measures ignition effects of hazardous materials (explosive materials) under airtight conditions by UN HAZARD CONTROL. Normally, it measures ignition cases that pressure of industrial packing status has exposure.

   
• UN Transport Standard of Goods
• EU REACH (Registration, Evaluation, Authorization and Restricton of CHemicals)
¨ç Analysis System by PLC Touch Screen
¨è Pressure Tank
It was made in Cylinder Type with 89mm in length and 60mm of outer diameter.
¨é Ventilation Plug
  It was made in Thread Type to fix Explosion Disk.
¨ê Spark Plug
  It was made to apply 5V from Power Supply as an ignition device. And, it has separate structure to test liquid and solid materials individually.
¨ë O-Ring
  The tester was equipped with Viton O-Ring so as to prevent pressure from leaking to the outside.
¨ì Side Arm
The tester could be equipped with Pressure Transducer to measure pressure in Tank. It was placed as far away from Pressure Tank as possible by connecting additional Teflon Hose for protection of Pressure Transducer.
¨í Tank Supporter
  It is used to fix the Pressure Tank as the Pressure Tank may be rushed out during test. It may be firmly fixed to the bottom of Main Chamber.
¨î DPT (Differential Pressure Transmitter) for Pressure Measurement
¨ï Automatic Ignition System (Electrical Detonator)
¨ð Explosion Disk for Over Pressure
Specification
Size 500(w) ¡¿ 284(D) ¡¿ 335(H)
Power 220 V AC, 60 Hz, 10 A
Weight 20 kg
Utilities Ignition primer, rupture disc
• Make another outside chamber, it can protect for liquids or powders from the explosion.
• Inside the chamber has attached the soundproof, therefore make noise is minimized from explosion.
• Safe explosion tester using auto ignition system (Remote Control Box)
• In pressure tank installed the DPT for automatically on pressure measurement.
• PLC Program for auto measurement of experimental data
• Touch Program to automatically check experimental data
• For over pressure, install the safety rupture disk on the tank.
• Auto pressure release system is enable to ventilate for safety after test
• Determine whether the gauge pressure reaches 2,070 kPa
• Determine whether the pressure reaches 2,070 kPa from 690 kPa in 30ms  
• Consider deflagration if the pressure reaches 2,070 kPa below 30ms
• Consider no or slow deflagration if the pressure reaches 2,070 kPa over 30ms